Analysis of accuracy of two different implant impression techniques

A comparative study

https://doi.org/10.53730/ijhs.v6nS6.11369

Authors

  • Bhushan Bangar Professor, Dept of Prosthodontics, Midsr Dental College Latur
  • Sashi Deepth Reddy J. Associate Professor (Dept. of Prosthodontics), Govt. Dental College and Hospital - Vijayawada
  • Shaik Mohammed Arif Professor, Department of Conservative Dentistry and Endodontics Care Dental College, Guntur Andhra Pradesh
  • Vipul Asopa Professor, Department of Prosthodontics, Pacific Dental College and Research Centre, Udaipur
  • Siddharth Swarup Associate Professor. Dept of Prosthodontics. Dr. D.Y. Patil Dental college and Hospital, Pimpri, Pune
  • Inderpreet Kaur B. DS Private Practitioner Amritsar Punjab India

Keywords:

implant, impression, accuracy, techniques

Abstract

Background: Comparatively evaluate the accuracy of two different implant impression techniques. Materials & methods: For the present study, reference models used were an edentulous mandibular cast with four implant analogues in the anterior region and a metallic insert in the posterior. Two impression techniques were studied as followed: Group 1: Polyvinyl siloxane impressions (putty and light body) using stock metal tray, and Group 2: Polyether impressions (medium body) using stock metal tray. Connection of the impression posts was done to implant analogues with the screws tightened manually such that their flat surfaces were facing buccally. The longer impression posts were connected to the anterior analogues and shorter were connected to the posterior analogues. A self-calibration test was performed to determine the accuracy obtained by the single evaluator. Results: Mean error among the specimens of Group 1 was 0.0441 while mean error among the specimens of Group 2 was 0.0425 respectively. While comparing the mean error among the two study groups, non-significant results were obtained. Conclusion: From the above results, the authors concluded that both the impression techniques can be used with equal effectiveness in implant procedures. 

Downloads

Download data is not yet available.

References

Alessandro Pozzi, Marco Tallarico, Francesco Mangani, Alberto Barlattani. Different implant impression techniques for edentulous patients treated with CAD/CAM complete-arch prostheses: a randomised controlled trial reporting data at 3 year post-loading. Eur J Oral Implantol. 2013 Winter;6(4):325-40.

Batara, R., Ardani, I. G. A. I., Wardani, I. A. K., Windiani, I. G. A. T., Adnyana, I. G. A. N. S., & Setiawati, Y. (2022). Psychogenic dysphagia in children, and the success of family-based treatment: Case report. International Journal of Health & Medical Sciences, 5(1), 163-168. https://doi.org/10.21744/ijhms.v5n1.1894

Bomberg TJ, Hatch RA, Hoffman W., Jr Impression material thickness in stock and custom trays. J Prosthet Dent. 1985;54:170–2.

Del’Acqua MA, Arioli-Filho JN, Compagnoni MA, Mollo Fde A., Jr Accuracy of impression and pouring techniques for an implant-supported prosthesis. Int J Oral Maxillofac Implants. 2008;23:226–36.

Gordon GE, Johnson GH, Drennon DG. The effect of tray selection on the accuracy of elastomeric impression materials. J Prosthet Dent. 1990;63:12–5.

Humberto Gennari Filho 1, José Vitor Quinelli Mazaro, Eduardo Vedovatto, Wirley Gonçalves Assunção, Paulo Henrique dos Santos. Accuracy of impression techniques for implants. Part 2 - comparison of splinting techniques. J Prosthodont. 2009 Feb;18(2):172-6.

Patil R, Kadam P, Oswal C, Patil S, Jajoo S, Gachake A. A comparative analysis of the accuracy of implant master casts fabricated from two different transfer impression techniques. J Int Soc Prevent Communit Dent 2016;6:142-8

Philips KM, Nicholls HZ, Ma T, Rubenstein J. The accuracy of three implant impression techniques: A three dimensional analysis. Int J Oral Maxillofac Implants. 1994;9:533–40.

Siadat H, Saeidi Z, Alikhasi M, Zeighami S. Comparative evaluation of the effect of impression materials and trays on the accuracy of angulated implants impressions. J Clin Exp Dent. 2018;10(11):e1096-e1102. Published 2018 Nov 1. doi:10.4317/jced.55227

Suryasa, I. W., Rodríguez-Gámez, M., & Koldoris, T. (2021). Get vaccinated when it is your turn and follow the local guidelines. International Journal of Health Sciences, 5(3), x-xv. https://doi.org/10.53730/ijhs.v5n3.2938

Treml A, Galvão GH, Giovanini AF, de Morais EC, Gonzaga CC, da Silva EM. Comparative evaluation of the accuracy of pick up transfer impressions performed with two different types of trays. RSBO. 2013;10:128–34.

Vigolo P, Fonzi F, Majzoub Z, Cordioli G. An evaluation of impression techniques for multiple internal connection implant prostheses. J Prosthet Dent. 2004;92:470–6.

Vojdani M, Torabi K, Ansarifard E. Accuracy of different impression materials in parallel and nonparallel implants. Dent Res J (Isfahan) 2015;12:315–22.

Published

01-08-2022

How to Cite

Bangar, B., Reddy, S. D. J., Arif, S. M., Asopa, V., Swarup, S., & Kaur, I. B. (2022). Analysis of accuracy of two different implant impression techniques: A comparative study. International Journal of Health Sciences, 6(S6), 7072–7076. https://doi.org/10.53730/ijhs.v6nS6.11369

Issue

Section

Peer Review Articles