Analysis of accuracy of two different implant impression techniques
A comparative study
Keywords:
implant, impression, accuracy, techniquesAbstract
Background: Comparatively evaluate the accuracy of two different implant impression techniques. Materials & methods: For the present study, reference models used were an edentulous mandibular cast with four implant analogues in the anterior region and a metallic insert in the posterior. Two impression techniques were studied as followed: Group 1: Polyvinyl siloxane impressions (putty and light body) using stock metal tray, and Group 2: Polyether impressions (medium body) using stock metal tray. Connection of the impression posts was done to implant analogues with the screws tightened manually such that their flat surfaces were facing buccally. The longer impression posts were connected to the anterior analogues and shorter were connected to the posterior analogues. A self-calibration test was performed to determine the accuracy obtained by the single evaluator. Results: Mean error among the specimens of Group 1 was 0.0441 while mean error among the specimens of Group 2 was 0.0425 respectively. While comparing the mean error among the two study groups, non-significant results were obtained. Conclusion: From the above results, the authors concluded that both the impression techniques can be used with equal effectiveness in implant procedures.
Downloads
References
Alessandro Pozzi, Marco Tallarico, Francesco Mangani, Alberto Barlattani. Different implant impression techniques for edentulous patients treated with CAD/CAM complete-arch prostheses: a randomised controlled trial reporting data at 3 year post-loading. Eur J Oral Implantol. 2013 Winter;6(4):325-40.
Batara, R., Ardani, I. G. A. I., Wardani, I. A. K., Windiani, I. G. A. T., Adnyana, I. G. A. N. S., & Setiawati, Y. (2022). Psychogenic dysphagia in children, and the success of family-based treatment: Case report. International Journal of Health & Medical Sciences, 5(1), 163-168. https://doi.org/10.21744/ijhms.v5n1.1894
Bomberg TJ, Hatch RA, Hoffman W., Jr Impression material thickness in stock and custom trays. J Prosthet Dent. 1985;54:170–2.
Del’Acqua MA, Arioli-Filho JN, Compagnoni MA, Mollo Fde A., Jr Accuracy of impression and pouring techniques for an implant-supported prosthesis. Int J Oral Maxillofac Implants. 2008;23:226–36.
Gordon GE, Johnson GH, Drennon DG. The effect of tray selection on the accuracy of elastomeric impression materials. J Prosthet Dent. 1990;63:12–5.
Humberto Gennari Filho 1, José Vitor Quinelli Mazaro, Eduardo Vedovatto, Wirley Gonçalves Assunção, Paulo Henrique dos Santos. Accuracy of impression techniques for implants. Part 2 - comparison of splinting techniques. J Prosthodont. 2009 Feb;18(2):172-6.
Patil R, Kadam P, Oswal C, Patil S, Jajoo S, Gachake A. A comparative analysis of the accuracy of implant master casts fabricated from two different transfer impression techniques. J Int Soc Prevent Communit Dent 2016;6:142-8
Philips KM, Nicholls HZ, Ma T, Rubenstein J. The accuracy of three implant impression techniques: A three dimensional analysis. Int J Oral Maxillofac Implants. 1994;9:533–40.
Siadat H, Saeidi Z, Alikhasi M, Zeighami S. Comparative evaluation of the effect of impression materials and trays on the accuracy of angulated implants impressions. J Clin Exp Dent. 2018;10(11):e1096-e1102. Published 2018 Nov 1. doi:10.4317/jced.55227
Suryasa, I. W., Rodríguez-Gámez, M., & Koldoris, T. (2021). Get vaccinated when it is your turn and follow the local guidelines. International Journal of Health Sciences, 5(3), x-xv. https://doi.org/10.53730/ijhs.v5n3.2938
Treml A, Galvão GH, Giovanini AF, de Morais EC, Gonzaga CC, da Silva EM. Comparative evaluation of the accuracy of pick up transfer impressions performed with two different types of trays. RSBO. 2013;10:128–34.
Vigolo P, Fonzi F, Majzoub Z, Cordioli G. An evaluation of impression techniques for multiple internal connection implant prostheses. J Prosthet Dent. 2004;92:470–6.
Vojdani M, Torabi K, Ansarifard E. Accuracy of different impression materials in parallel and nonparallel implants. Dent Res J (Isfahan) 2015;12:315–22.
Published
How to Cite
Issue
Section
Copyright (c) 2022 International journal of health sciences
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Articles published in the International Journal of Health Sciences (IJHS) are available under Creative Commons Attribution Non-Commercial No Derivatives Licence (CC BY-NC-ND 4.0). Authors retain copyright in their work and grant IJHS right of first publication under CC BY-NC-ND 4.0. Users have the right to read, download, copy, distribute, print, search, or link to the full texts of articles in this journal, and to use them for any other lawful purpose.
Articles published in IJHS can be copied, communicated and shared in their published form for non-commercial purposes provided full attribution is given to the author and the journal. Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in this journal.
This copyright notice applies to articles published in IJHS volumes 4 onwards. Please read about the copyright notices for previous volumes under Journal History.