Functional outcome of minimal invasive anterior bridge plating for humerus shaft fractures

https://doi.org/10.53730/ijhs.v6nS6.12608

Authors

  • Priyank R. Pancholi Assistant Professor, Department of Orthopaedics, Parul Institute of Medical Sciences & Research, Parul Sevashram Hospital, Waghodia, Vadodara, Gujarat, India
  • Niravkumar Prabhudas Moradiya Assistant Professor, Department of Orthopaedics, SMIMER Hospital and Medical College, Surat, Gujarat India
  • Khatri Chaitanya Nileshkumar Senior resident, Department of Orthopaedics, Pacific institute of medical sciences, Umarda, Udaipur, Rajasthan, India

Keywords:

anterior bridge plating, diaphyseal fractures, shaft humerus, minimally invasive plating

Abstract

Objectives: To study clinical & functional outcomes and complications in patients with humeral shaft fractures treated using anterior bridge plating. Materials and Methods: 25 patients with fractures of middle third humerus were treated with Minimum invasive Anterior Bridge plating in a case study at tertiary care hospital Surat. Both male and female patients above 20 years of age with closed and OG type I & II diaphyseal fractures of Humerus were included. Pathologic fracture, OG III fractures, Fractures in skeletally immature patients, Old neglected fractures, Those who Refused to provide informed consent and Fractures with neuromuscular disorders / neurovascular insufficiency were excluded. Functional outcome where analyzed by constant murley shoulder outcome score &Mayo elbow performance index. Results: The totals of twenty-five patients were included in the study. Out of total twenty-five patients 17 were males and 8 were females with the average age of 39 years. Right side fracture was found in 20 patients out of total 25. The average time for the surgery for the entire patient was 68 minutes. 

Downloads

Download data is not yet available.

References

Ajmal M, et al. Antegrade locked intra medullary nailingin humeral shaft fractures. Injury, 2001; 32:692-4.

Apivatthakakul T, Arpornchayanon O, Bavornratanavech S.Minimally invasive plate osteosynthesis (MIPO) of the humeralshaft fracture: Is it possible? A cadaveric study and preliminaryreport. Injury 2005;36:530 8.

Apivatthakakul T, et al. MIPO of the humeral shaftfracture: Is it possible? A cadaveric study andpreliminary report. Injury, 2005; 36:530-8.

Aronson J. for Bone Regeneration and Repair. Bone Regeneration and Repair. Biol Clin Applications. 2005: 195.

Baumgaertel F, Buhl M. Fracture healing in biologicalplate osteosynthesis. Injury, 1998; 29 (Suppl 3):C3-6.

Camden P. Fracture bracing of the humerus. Injury 1992;23:245-8.

Chao TC et al. Humeral shaft fractures treated by DCP,Ender and interlocking nails. Int Orthop, 2005; 29:88-91.

Concha JM, Sandoval A, Streubel PN. Minimally invasiveplate osteosynthesis for humeral shaft fractures: are results reproducible? Int Orthop. 2010;34(8):1297-305.

Dickson KF, Munz JW. Biomechanics and biology ofLocked plating: Tech Orthop, 2007; 22:4.

Frigg R, Wagner M. AO Manual of fracture management.Chapters 1.2: Concepts of fracture fixation, 2006.

Greiwe R. Proximal humerus fractures: Percutaneous fixation, proximal humeral nailing, and open reduction and internal fixation. Shoulder and Elbow Trauma and its Complications. The Shoulder. 2015;1:83.

Hunter SG. The closed treatment of fractures of thehumeral shaft. Clin Orthop Relat Res. 1982; 164:192-8.

Iwegbu G. Principles and management of acute orthopaedic trauma. AuthorHouse; 2015.

Jiang R, Luo CF, Zeng BF, Mei GH. Minimally invasiveplating for complex humeral shaft fractures. Arch Orthop Trauma Surg. 2007;127(7):531-5.

Kim JW, Oh CW, Byun YS, Kim JJ, Park KC. A prospectiverandomized study of operative treatment for noncomminuted humeral shaft fractures: conventional open plating versus minimal invasive plate osteosynthesis. J Orthop Trauma. 2015;29(4):189-94.

Kiran K. A study of surgical management of diaphyseal fractures of humerus in adults by open reduction and internal fixation with dynamic compression plate and screws. RGUHS. 2006.

Livani B, et al. Is MIPO in humeral shaft fractures reallysafe? Postoperative ultra sonographic evaluation. Int Orthop, 2009; 33:1719-23.

Mafaldo-Gómez, D. A., & Reyes-Meza, O. B. (2022). Training in values in environmental education in high school students: Case study: Education, environment, and society. International Journal of Life Sciences, 6(2), 65–71. https://doi.org/10.53730/ijls.v6n2.10561

Malhan S, Thomas S, Srivastav S, et al. Minimally invasive plate osteosynthesis using a locking compression plate for diaphyseal humeral fractures. J Orthop Surg (Hong Kong). 2012;20(3):292-6.

Matsunaga FT, Tamaoki MJ, Matsumoto MH, dos Santos JB,Faloppa F, Belloti JC. Treatment of the humeral shaft fractures: minimally invasive osteosynthesis with bridge plate versus conservative treatment with functional brace: study protocol for a randomised controlled trial. Trials. 2013; 14:246.

Parihar, N., Vyas, A., Srivastava, R., Razdan, R. A., Jaiswal, T., & Patel, V. (2022). Comparative evaluation of sulcus/ vestibular depth by intraoral examination and on master cast/denture in completely edentulous cases. International Journal of Health Sciences, 6(S2), 12361–12372. https://doi.org/10.53730/ijhs.v6nS2.8275

Petsatodes G, et al. Antegrade interlocking nailing ofhumeral shaft fractures. J Orthop Sci, 2004; 9:247-52.

Santori FS, Santori N. The Exp Nail for the treatment ofdiaphyseal humeral fractures. JBJS Br. 2002; 84(Supp3):280.

Sarmiento A, Latta L. Functional fracture bracing: tibia, humerus, and ulna. Springer Science & Business Media. 1995.

Shetty MS, Kumar MA, Sujay K, Kini AR, Kanthi KG. Minimallyinvasive plate osteosynthesis for humerus diaphyseal fractures. Indian J Orthop. 2011;45(6):520-6.

Suryasa, I. W., Rodríguez-Gámez, M., & Koldoris, T. (2021). Health and treatment of diabetes mellitus. International Journal of Health Sciences, 5(1), i-v. https://doi.org/10.53730/ijhs.v5n1.2864

Wagner M, Frenk A. Locked plating: Biomechanics andbiology and locked plating: Clinical indications. Tech Orthop 2007; 22:4.

Wang C, Li J, Li Y, Dai G, Wang M. Is minimally invasiveplating osteosynthesis for humeral shaft fracture advantageous compared with the conventional open technique? J Shoulder Elbow Surg. 2015;24(11):1741-8.

Wang ZH, Xiang M, Xie J, Tang HC, Chen H, Liu X. Treatmentof humerus shaft fractures using minimally invasive percutaneous plate osteosynthesis through anterior approach. Zhongguo Gu Shang. 2009;22(9):681-3.

Zhiquan A, Bingfang Z, Yeming W, Chi Z, Peiyan H. Minimallyinvasive plating osteosynthesis (MIPO) of middle and distal third humeral shaft fractures. J Orthop Trauma. 2007; 21(9):628-33.

Zhiquan A, et al. Minimally invasive platingosteosynthesis (MIPO) of middle and distal third humeralshaft fractures. J Orthop Trauma, 2007; 21:628-33.

Ziran BH, et al. Percutaneous plating of the humerus withlocked plating: Technique and case report. J Trauma In jInfect Crit Care, 2007; 63:205-10.

Published

10-09-2022

How to Cite

Pancholi, P. R., Moradiya, N. P., & Nileshkumar, K. C. (2022). Functional outcome of minimal invasive anterior bridge plating for humerus shaft fractures. International Journal of Health Sciences, 6(S6), 9782–9791. https://doi.org/10.53730/ijhs.v6nS6.12608

Issue

Section

Peer Review Articles

Most read articles by the same author(s)