Assessment of staff of radiology department annual effective doses during bone scans

https://doi.org/10.53730/ijhs.v6nS10.13995

Authors

  • Mohammad Uzair MBBS, Resident Radiology (Fcps II trainee), PNS Shifa
  • Ayatullah Roohullah Khumaini MBBS. FCPS, Consultant Radiologist, Head of Radiology Department, CMH Okara
  • Sumera Mahar Consultant Radiologist National institute of Rehabilitation medicine (NIRM) Hospital Islamabad
  • Marya Hameed Head of Radiology Department, National Institute of child health Karachi/JSMU
  • Farah Naz Magsi Consultant Radiologist, JPMC Karachi
  • Khushboo Chandio B.S Nursing (Generic) Ms nursing (continue) Leture people's Nursing School LUMHS Jamshoro

Keywords:

dosimetry, effective radiation dose, occupational doses, x-rays

Abstract

Background: The most frequent imaging techniques used by NM departments are skeletal scintigraphy and bone scans. To assess the protective measures and the anticipated radiation hazards, it is crucial to evaluate the patient's doses for the NMC staff. Objectives: Current research intended to evaluate the annual effective doses of radiology department’s staff during bone scans and their health hazards due to radiation. Methods: The study was executed at Nuclear Medical Center, in October 2022 and annual effective dose of radiologists were measured implying the two techniques including 99mTc-MDP TLDs, carrying two dose quantities of Hp (10) and Hp (0.07) and GR-200A TLDs (LiF: Mg, Cu, P). Results: Effective dose of operators was evaluated using 99mTc-MDP TLDs, was found that the mean personal equivalent dosimetry of HP 10 was 0.43 (0.12-0.74) and HP 0.07 was 0.52 (0.11-0.76). Relative strength of residual signal for successive readouts of LiF: Mg, Cu, P chips made had mean GR-200A and Ref. 10 of 0.54+0.23 and 3.10+1.12, respectively. Conclusion: The radiographers in all of the X-ray facilities were well aware of radiation safety and the staff's occupational dosages of HP(0.07) and HP (10) were within the recommended limits. 

Downloads

Download data is not yet available.

References

Saeed MK, Almalki Y. Assessment of the occupational dose and radiogenic risk in diagnostic radiology and nuclear medicine examinations. Int J Rad Res. 2021;19(2):365-372.

International Commission on Radiological Protection ICRP. The 2007 recommendations of the international commission on radiological protection. ICRP Pub. 2007;103, Pergamon Press, Oxford.

Ko J, Kim Y. Evaluation of effective dose during X-ray training in a radiological technology program in Korea. J Rad Res Appl Sci. 2018;11:383-392.

Mattar EH. Assessment of Patient and Staff Annual Effective Doses at a Nuclear Medicine Department during Bone Scans. Open J Radiol. 2022;12:155-162.

Edam AI, Sulieman A, Tamam N, Abuelhaia E, Salih I, Sam AK, Yousef M, Alkhorayef M, Bradley DA. Current Sudan Protective Practice in Diagnostic Nuclear Medicine and Patient Dose. Rad Phy Chem. 2021;178:108997.

Guira O, Ouédraogo A, Zoungrana L, Bognounou R, Traoré S, Tondé A, Drabo J. Quality of Diabetes Annual Management in the Internal Medicine Department in Yalgado Ouédraogo Teaching Hospital, Ouagadougou. Open J Int Med. 2020;10:256-262.

Alyami J, Nassef MH. Assessment of Diagnostic Radiology Facilities Technical Radiation Protection Requirements in KSA. Appl Sci. 2022;12:284.

Sakin GAE, Elfadil M, Gar-elnabi M, Omer MAA, Omer, M, Ali RB, Esmeal M. Assessment of effects induced by bone scintigraphy dose in red & white blood cells relative to ageing and obesity. MOJ Pub Heal. 2020;9(5):160-164.

Ali W, Sulieman A, Tamam N, Boshara NA, Aldhebaib A, Alkhorayef M, Khandaker MU, Bradley DA. Estimation of Patients Organ Doses and staff Exposure during Bone Scan Examination. Radiation Phy Chem. 2021;188:109693.

Nassef MH, Kinsara AA. Occupational Radiation Dose for Medical Workers at a University Hospital. J Taibah Uni Sci. 2017;11:1259–1266.

Soliman KM, Alenezi A, Alruwaili T, Altimyat S, Alrushoud A, Alkhorayef M. Five Years Reviof Occupational Dosimetry Program at A Tertiary Care Hospital and Comparison with UNSCEAR 2008 Report. Int J Radiol. 2018;4:157–160.

Smart R. Task-specific monitoring of nuclear medicine technologists’ radiation exposure. Rad Protect Dosim. 2004;109:201–209.

Pant G, Sharma S, Rath G. Finger doses for staff handling radiopharmaceuticals in nuclear medicine. J Nucl Med Technol. 2006;34(3):169–173.

Shen W, Tang K, Zhu H, Liu B. New advances in LiF: Mg, Cu, P TLDs (GR-200A). Rad Prot Dosimtery. 2002;100(1-4):357-360.

Sharma R, Purohit RK. Protective role of liv.52 against radiation and cadmium induced haematological changes in the Swiss albino mice. Int J Life Sc Bt Pharm Res. 2012;1(3):114–123.

Alashban Y. An assessment of occupational effective dose in several medical departments in Saudi Arabia. J King Saud Univ Sci. 2021;33:1–5.

Sulieman A, Yousif E, Alkhorayef M, Mattar E, Babikir E, Bradley D. Lens dose and radiogenic risk from 99mTc nuclear medicine examinations. J Radioanal Nucl Chem. 2018;318:797–801.

Saez-Vergara JC. Recent Developments of passive and active detectors used in the monitoring of external environmental radiation. Radiat Prot Dosim. 2000;92(1–3):83–88.

Published

22-02-2023

How to Cite

Uzair, M., Khumaini, A. R., Mahar, S., Hameed, M., Magsi, F. N., & Chandio, K. (2023). Assessment of staff of radiology department annual effective doses during bone scans. International Journal of Health Sciences, 6(S10), 1332–1339. https://doi.org/10.53730/ijhs.v6nS10.13995