Correlation of bone density, body mass index and radiation dose in the digital radiography system

https://doi.org/10.53730/ijhs.v6nS2.6978

Authors

  • Woo-Taek Lim Dept. of Radiology, KonKuk University Medical Center, 120-1, Neungdong-ro, Gwangjin-gu, Seoul, 05030, Republic of Korea
  • Sang-Hyun Kim Dept. of Radiological Science, Shin-Han University, 95, Hoam-ro, Uijeongbu-si, Gyeonggi-do, 11644, Republic of Korea

Keywords:

bone mineral density, body mass index, digital radiography, diagnostic reference level, medical exposer

Abstract

Background/Objectives: This study aims to provide the direction for reducing the exposure dose in patients by analyzing the PACS data of patients who received both lumbar spine bone mineral density & lumbar spine X-ray examination, understanding the correlation between BMD & BMI of the DR system, and mAs, finding the dose determinants, and then providing the basic data for the calculation of diagnostic reference level of Korean people.Methods/Statistical analysis: Focusing on the bone mineral density test data saved in PACS, this study researched the data of patients who received the lumbar spine X-ray within four months from the test date. The BMI and BMD were recorded through the bone mineral density image while the mAs and kVp were recorded through the bone spine X-ray image.Findings: Results of the multiple regression analysis, only the BMI showed the causality with mAs while the BMD and T-score did not have significant causality with dose.Improvements/Applications: The BMI formed the linear causality with medical exposure of patients. Therefore, if this is used as a tool for calculating the dose by the novice radiological technologists who have just started their radiographic work, it would be possible to reduce the unnecessary exposure of patients. 

Downloads

Download data is not yet available.

References

Hsu JC, Nieves LM, Betzer O, Sadan T, Noël PB, Popovtzer R, et al. Nanoparticle contrast agents for X‐ray imaging applications. Wiley Interdisciplinary Reviews: Nanomedicine and Nanobiotechnology. 2020;12(6):e1642.

Shim JN, Lee YG, Lee YJ. Estimation of absorbed dose for anterior and posterior organs with body mass index in standing whole spine examination. Journal of the Institute of Electronics and Information Engineers. 2016;53(12):147-51.

Jo GH, Kang YH, Kim BS. A study on the exposure parameter and the patient dose for Digital Radiography system in Dae Goo. Journal of radiological science and technology. 2008;31(2):177-82.

Lee JI. A Study on the Dose Indicator for Digital radiography. The Graduate School Yonsei University. 2008.

Kim GP. Assessment of Radiation Exposure of Korean Population by Medical Radiation. Korea Disease Control and Prevention Agency: Korea Disease Control and Prevention Agency; 2020. Report No.: 11-1790387-000030-01.

Koo NH, Yoon HS, Choi KW, Lee JE, Kim JJ. The Effect of Body Mass Index on Entrance Surface Air Kerma in Abdominal X-ray Radiography Using Automatic Exposure Control. Journal of the Korean Society of Radiology. 2018;12(5):659-67.

Hwang JH, Lee KB. A study on the quantitative analysis method through the absorbed dose and the histogram in the performance evaluation of the detector according to the sensitivity change of auto exposure control (AEC) in DR (digital radiography). The Journal of the Korea Contents Association. 2018;18(1):232-40.

Mettler Jr FA, Mahesh M, Bhargavan-Chatfield M, Chambers CE, Elee JG, Frush DP, et al. Patient exposure from radiologic and nuclear medicine procedures in the United States: procedure volume and effective dose for the period 2006–2016. Radiology. 2020;295(2):418-27.

Kumar, S. (2022). A quest for sustainium (sustainability Premium): review of sustainable bonds. Academy of Accounting and Financial Studies Journal, Vol. 26, no.2, pp. 1-18

Jeon Ch, Kim JO, Lee YJ, Lee JE, Lee CH, Min BI. The Radiation Protection effect of Tabebuia Avellanedae Extract on the Prostate in Male Rats. Journal of the Korean Society of Radiology. 2020;14(6):755-62.

Kim HJ, Lee CL. Physical Aspects and International Trends of Medical Radiation Exposure. Journal of the Korean Society of Imaging Informatics in Medicine. 2011;17(1):1-9.

Park H, Yoon Y, Kim J, Kim J, Jeong H, Tanaka N, et al. Use of clinical exposure index and deviation index based on national diagnostic reference level as dose-optimization tools for general radiography in Korea. Radiation Protection Dosimetry. 2020;191(4):439-51.

Rodgers CC. Low-dose X-ray imaging may increase the risk of neurodegenerative diseases. Medical hypotheses. 2020;142:109726.

Tsapaki V. Radiation dose optimization in diagnostic and interventional radiology: Current issues and future perspectives. Physica Medica. 2020;79:16-21.

Huda W, Abrahams RB. Radiographic techniques, contrast, and noise in x-ray imaging. American Journal of Roentgenology. 2015;204(2):W126-W31.

Malekzadeh M, Asadi M, Abbasi-Rad S, Abolghasemi J, Hamidi Z, Talebi M, et al. MDCT-QCT, QUS, and DXA in healthy adults: An intermodality comparison. Medical journal of the Islamic Republic of Iran. 2019;33:156.

Published

06-05-2022

How to Cite

Lim, W.-T., & Kim, S.-H. (2022). Correlation of bone density, body mass index and radiation dose in the digital radiography system. International Journal of Health Sciences, 6(S2), 7931–7938. https://doi.org/10.53730/ijhs.v6nS2.6978

Issue

Section

Peer Review Articles