Anode heel effect application with step wedge against effect of signal to noise ratio in computed radiography
Keywords:
AHE, computed radiography, image, SNR, step wedgeAbstract
It was researched on the application of Anoda Heel Effect (AHE) with a step wedge on the effect of Signal To Noise Ratio (SNR) on Computed Radiography (CR) has been carried out. This research was conducted on a 21 step wedge with two treatments, namely the application of AHE and without the application of AHE. This measurement is repeated three times on radiographs to obtain a total image of six images (without the application of AHE as many as three images and with the application of AHE as many as three images). The results of taking radiographs using AHE and without AHE were measured using the RadiAnt Dicom Viewer program. The SNR value on the step wedge image without the AHE application has an average of 26.89. The SNR value on the step wedge image using AHE is 60.54. The results of the correlation test (Pearson correlation test) on the SNR showed that there was a significant and very strong effect of the application of AHE on the step wedge on the SNR in CR (p-value <0.001 and the R-value ranging from 0.600 to 0.799).
Downloads
References
Carlton, R. R., & Adler, A. M. (2012). Principles of Radiographic Imaging (Book Only). Cengage Learning.
Cowen, A. R., Davies, A. G., & Kengyelics, S. M. (2007). Advances in computed radiography systems and their physical imaging characteristics. Clinical radiology, 62(12), 1132-1141. https://doi.org/10.1016/j.crad.2007.07.009
Dahlan, M. S. (2011). Statistik untuk kedokteran dan kesehatan. Penerbit Salemba.
Desai, N., Singh, A., & Valentino, D. J. (2010). Practical evaluation of image quality in computed radiographic (CR) imaging systems. In Medical Imaging 2010: Physics of Medical Imaging (Vol. 7622, p. 76224Q). International Society for Optics and Photonics.
Fauber, T. L. (2016). Radiographic Imaging and Exposure-E-Book. Elsevier Health Sciences.
Gede, P. S. L., Ratini, N. N., & Iffah, M. (2020). Pengaruh Variasi Tegangan Tabung Sinar-X terhadap Signal to Noise Ratio (SNR) dengan Penerapan Anode Heel Effect menggunakan Stepwedge. BULETIN FISIKA, 22(1), 20-28.
Gibson, D. J., & Davidson, R. A. (2012). Exposure creep in computed radiography: a longitudinal study. Academic radiology, 19(4), 458-462. https://doi.org/10.1016/j.acra.2011.12.003
Kenneth, L. B. (2014). Textbook of radiographic positioning and related anatomy. Elsevier mosby.
Korner, M., Weber, C. H., Wirth, S., Pfeifer, K. J., Reiser, M. F., & Treitl, M. (2007). Advances in digital radiography: physical principles and system overview. Radiographics, 27(3), 675-686.
Larsson, E. G., Erdogmus, D., Yan, R., Principe, J. C., & Fitzsimmons, J. R. (2003). SNR-optimality of sum-of-squares reconstruction for phased-array magnetic resonance imaging. Journal of Magnetic Resonance, 163(1), 121-123. https://doi.org/10.1016/S1090-7807(03)00132-0
Louk, A. C., & Suparta, G. B. (2014). Pengukuran Kualitas Sistem Pencitraan Radiografi Digital Sinar-X. BIMIPA, 24(2), 149-166.
Ma, W. K., Hogg, P., Tootell, A., Manning, D., Thomas, N., Kane, T., ... & Kitching, J. (2013). Anthropomorphic chest phantom imaging–the potential for dose creep in computed radiography. Radiography, 19(3), 207-211. https://doi.org/10.1016/j.radi.2013.04.002
Maintz, J. A., & Viergever, M. A. (1998). A survey of medical image registration. Medical image analysis, 2(1), 1-36. https://doi.org/10.1016/S1361-8415(01)80026-8
McInerney, T., & Terzopoulos, D. (1996). Deformable models in medical image analysis: a survey. Medical image analysis, 1(2), 91-108. https://doi.org/10.1016/S1361-8415(96)80007-7
Medixant. (2016). RadiAnt DICOM Viewer. Version 3.0.2
Ratini, N. N., Yuliara, I. M., & Trisnawati, N. L. P. (2019). Radiation dosage distribution in area room CT scan multi slice 64 to dose limit value. International journal of health sciences, 3(3), 25-32.
Sudin, A., Widyandari, H., & Muhlisin, Z. (2015). Studi Pengaruh Ukuran Pixel Imaging Plate Terhadap Kualitas Citra Radiograf. Youngster Physics Journal, 4(3), 225-230.
Published
How to Cite
Issue
Section
Copyright (c) 2020 International journal of health sciences
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Articles published in the International Journal of Health Sciences (IJHS) are available under Creative Commons Attribution Non-Commercial No Derivatives Licence (CC BY-NC-ND 4.0). Authors retain copyright in their work and grant IJHS right of first publication under CC BY-NC-ND 4.0. Users have the right to read, download, copy, distribute, print, search, or link to the full texts of articles in this journal, and to use them for any other lawful purpose.
Articles published in IJHS can be copied, communicated and shared in their published form for non-commercial purposes provided full attribution is given to the author and the journal. Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgment of its initial publication in this journal.
This copyright notice applies to articles published in IJHS volumes 4 onwards. Please read about the copyright notices for previous volumes under Journal History.