Analysis of serum metal ion levels in dental implant patients

https://doi.org/10.53730/ijhs.v6nS5.9940

Authors

  • Ravinder Singh Saini Associate Professor, COAMS, King Khalid University, Abha, Saudi Arabia
  • Kanwalpreet Kaur MDS, Pediatric and Preventive Dentistry, Consultant Pediatric Dentist, Ludhiana, Punjab

Keywords:

Metal, Ions, Dental

Abstract

Background: Dental implants have been widely used for the replacement of missing teeth in fully and partially edentulous patients. Titanium (Ti) has been the material of choice for dental implants due to its superior corrosion resistance behaviour and desirable mechanical properties. Hence; the present study was undertaken for assessing the serum metal ion levels in Dental Implant Patients. Materials & methods: A total of 20 subjects with missing mandibular first molar and scheduled for prosthetic rehabilitation for same using dental implant therapy were enrolled. Blood samples were obtained at baseline and sent to laboratory where auto-analyser was used for evaluation of metal ions levels. All the dental implant procedures were carried out under the hands of skilled implantologists. After placement of dental implants, blood samples were obtained at 8 weeks and 6 months follow-up. Metal ions were assessed at subsequent follow-ups. All the results were analysed by SPSS software. Results: Mean serum titanium concentration at baseline, 8 weeks and 6 months was fond to be 2.39 mg/dL, 2.35 mg/dL and 2.38 mg/dL respectively. Mean serum aluminium concentration at baseline, 8 weeks and 6 months was fond to be 4.19 mg/dL, 4.16 mg/dL and 4.18 mg/dL respectively.

Downloads

Download data is not yet available.

References

De Morais LS et al. Systemic levels of metallic ions released from orthodontic mini-implants.Am J OrthodDentofacialOrthop. 2009 Apr;135(4):522-9

A.Sarmiento-González et al. Titanium levels in the organs and blood of rats with a titani um implant, in the absence of wear, as determined by double-focusing ICP-MS. Anal BioanalChem (2009) 393:335– 343.

Janie Barry, Martin Lavigne and Pascal-Andre, Vendittoli. Evaluation of the Method for Analyzing Chromium, Cobalt and Titanium Ion Levels in the Blood Following Hip Replacement with a Metal-onMetal Prosthesis. Journal of Analytical Toxicology 2013;37:90 – 96.

Barry Sampson and Alister Hart. Clinical usefulness of blood metal measurements to assess the failure of metal-on-metal hip implants. Ann ClinBiochem 2012; 49: 118 – 131

Bortagaray, M.A.; Ibañez, C.A.A.; Ibañez, M.C.; Ibañez, J.C. Corrosion Analysis of an Experimental Noble Alloy on Commercially Pure Titanium Dental Implants. Open Dent. J. 2016, 10, 486–496.

Jeffery EH, Abreo K, Burgess E, Cannata J, Greger JL. Systemic aluminum toxicity: Effects on bone, hematopoietic tissue, and kidney. J Toxicol Environ Health. 1996;48:649–65.

Goldfine AB, Patti ME, Zuberi L, Goldstein BJ, LeBlanc R, Landaker EJ, et al. Metabolic effects of vanadyl sulfate in humans with non-insulin-dependent diabetes mellitus: In vivo and in vitro studies. Metabolism. 2000;49:400–10.

Mercuri LG, Miloro M, Skipor A, Sukatjo C, Mathew MT. Serum metal levels in maxillofacial reconstructive surgery patients. J Oral Maxillofac Surg. 2019;77:e59

AlOtaibi, A.; Sherif, E.-S.M.; Zinelis, S.; Al Jabbari, Y.S. Corrosion behavior of two cp titanium dental implants connected by cobalt chromium metal superstructure in artificial saliva and the influence of immersion time. Int. J. Electrochem. Sci. 2016, 11, 5877–5890.

Pozhitkov, A.E.; Daubert, D.; Brochwicz Donimirski, A.; Goodgion, D.; Vagin, M.Y.; Leroux, B.G.; Hunter, C.M.; Flemmig, T.F.; Noble, P.A.; Bryers, J.D. Interruption of Electrical Conductivity of Titanium Dental Implants Suggests a Path Towards Elimination of Corrosion. PLoS ONE 2015, 10, e0140393.

Akbarov, A. N., & Xabilov, D. N. U. (2021). The condition of the oral cavity in patients who have had a viral infection COVID-19. International Journal of Health & Medical Sciences, 4(4), 381-383. https://doi.org/10.21744/ijhms.v4n4.1796

Gopi G, Shanmugasundaram S, Krishnakumar Raja VB, Afradh KM. Evaluation of Serum Metal Ion Levels in Dental Implant Patients: A Prospective Study. Ann Maxillofac Surg. 2021;11(2):261-265.

Suryasa, I. W., Rodríguez-Gámez, M., & Koldoris, T. (2021). Get vaccinated when it is your turn and follow the local guidelines. International Journal of Health Sciences, 5(3), x-xv. https://doi.org/10.53730/ijhs.v5n3.2938

Temiz M, Dayi E, Saruhan N. Evaluation of Blood Titanium Levels and Total Bone Contact Area of Dental Implants. Biomed research international. 2018; 4121639.

Published

29-06-2022

How to Cite

Saini, R. S., & Kaur, K. (2022). Analysis of serum metal ion levels in dental implant patients. International Journal of Health Sciences, 6(S5), 5645–5649. https://doi.org/10.53730/ijhs.v6nS5.9940

Issue

Section

Peer Review Articles

Most read articles by the same author(s)